SM 302 safety relay

     

     As the most important part of safety loop, safety controller/safety PLC has been recognized by more and more people, but in the process of use, there are still many users who are confused about the differences between safety relay and ordinary relay, so I would like to share them with you here. As we all know, we must remember three words in the concept of safety design:

(1) Redundancy

(2) Difference

(3) Self-detection

        How to construct the safety loop with the reliability above PLd, the safety controller must become an important link. The safety loop consists of safety input, safety control and safety output subsystems, and the safety control "including safety relay, safety controller, safety PLC, etc." realizes the safety control function. Designers match different safety controllers to achieve the reliability level of the safety loop according to the number of products at the input end.


▊ SM-302 programmable safety controller
1666939573713918.png

· Is a configurable safety controller, which supports the input of various safety product components.

·Maximum support for 3 sets of dual-loop inputs.

·Iso 13849-1 performance index PLe

·Built-in self-diagnosis function for fault detection

·Modbus protocol communication

·Input and output fault indicator light

·Safety certification: PL e, Cat: 4


Product selection

product name

model

Safety input

Safe output

brand

Programmable safety controller

SM-302

3CH

2NO

LHS
explain

Up to 3 sets of dual-channel security products can be entered.

The programming software defines the field safety products by itself.

Official website programming software download connection.:http://lhsafety.com.cn/showinfo-257-118-0.html


safety performance

·Performance level (PL): PLE

·Safety category (cat.): cat.4.

·Task time (TM): 20 years.

·Diagnostic coverage (DC/DC AVG): 99%

·Safety integrity level (SIL): SIL3

·Hardware fault margin (HFT): 1

·Safety Failure Score (SFF): 99%

·PFHD: 1.78e-9/h

·Stop category: 0/1               

Comply with the standard EN ISO13849

Comply with the standard EN ISO13849

Comply with the standard EN ISO13849

Comply with the standard EN ISO13849

Comply with standards IEC61508, IEC62061.

Comply with standards IEC61508, IEC62061.

Comply with standards IEC61508, IEC62061.

Comply with standards IEC61508, IEC62061.

Comply with standard EN 60204-1.


Main technical parameters

Power supply characteristics

·Power supply voltage: 24VDC

·Voltage range: 20~30VDC

·Current loss: ≤100mA(24VDC)

Input characteristics

·Input current: ≤10mA(24VDC)

·Conductor resistance: ≤15Ω

·Input equipment: emergency stop button, safety door, two-hand button,

·Safety light curtain, magnetic switch, etc

·Input channel: 3

output characteristic

·Number of contacts: 2NO (safety output)

·Contact material: AgSnO2

·Contact fuse protection: 10A is fast, 6A is slow.

·Switching capacity: 5A/230VAC;; 5A/24VDC

Time characteristic

·Suction buffer time:≤100ms

·Release buffer time:≤30ms

·Recovery time:

         Emergency stop operation:≤30ms

         Power failure:≤1000ms

·Recovery time:

         Emergency stop operation:≤30ms

         Power failure:≤100ms

·Short-term interruption of power supply:20ms

Communication characteristics

·Baud rate: 38.4kbps (fixed)

·Communication length: ≤1000m

·Networking capacity: ≤10 units


Environmental characteristic parameters

·Electromagnetic compatibility: comply with EN60947, EN61000-6-2 and EN61000-6-4.

·Vibration frequency: 10Hz~55Hz

·Vibration amplitude: 0.35mm

·Operating temperature: -20℃~+60℃

·Storage temperature: -40℃~+85℃

·Relative humidity: 10%~90%

·Overvoltage grade: Ⅲ

·Pollution level: 2

·Altitude: ≤2000m

·Rated isolation voltage: 250VAC.

·Rated impulse voltage: 6000V(1.2/50us)

·Insulation strength: 1500VAC for 1min.

·Electrical clearance and creepage distance: in accordance with EN60947-1.

302 22.10.27處理過原圖加了影印.png


Functional application parameters

functional block diagram

Typical application

圖片3.png

圖片4.png


Input element: CH1 (emergency stop button); CH2 (emergency stop button); CH3 (reset button)

Control Logic: CH1&CH2

Reset mode: manual reset.

Output delay: 0s

Safety level: Cat.4 performance level: PLe safety integrity level: SIL 3


Wiring diagram

Power Supply 

1.png

correspondence

1655948458157829.png

input

1655948540921377.png1655948633175148.png1655948716671157.png
6.png7.png
9.png10.png

reset

11.png12.png

feedback

13.png14.png

output

15.png

     


Related Products
Download
PDF file download
Video file download
Previous

Contact us

400-881-6062

Lihong Safety Equipment Engineering (Shanghai) Co., Ltd.

E-Mail: info@lh-safety.com

Address: 581 Xiuchuan Road, Chuansha Town, Pudong New District, Shanghai

(Greenland East Coast International Plaza-Room A 313)

Copyright ? Lihong Safety Equipment Engineering (Shanghai) Co., Ltd.  ICP19034341-1  Technical Support: lanjujing

Online service

Online message

  • Click to refresh
  • 主站蜘蛛池模板: 又大又长粗又爽又黄少妇毛片 | 中文字幕人成无码免费视频| 亚洲AV无码乱码A片秀色直播| aaa欧美色吧激情视频| 18精品久久久无码午夜福利| 麻豆一区二区三区精品视频| 亚洲精品制服丝袜四区| 人妻精品久久无码区| 亚洲一区二区三区乱码在线欧洲| 麻豆成人传媒一区二区| 亚洲国产成人精品av在线| 免费天堂无码人妻成人av电影| 日韩精品射精管理在线观看| 亚洲欧洲日产国码久在线| 国产亚洲精品久久久久妲己| 2019精品手机国产品在线 | 玩弄美艳馊子高潮无码| 国产成网站18禁止久久影院 | 国产精品自在自线视频| 久久国产亚洲精品超碰热| 国产午夜成人久久无码一区二区| 国产精品成人免费视频一区| 国产精品福利视频导航| 国产超碰人人做人人爽av动图| 亚洲国内自拍愉拍| 成年动漫18禁无码3d动漫| 欧洲乱码伦视频免费国产 | 亚洲国产欧美日韩在线人成| 久久精品一区二区三区av| 欧美丰满熟妇aaaaa片| 女明星黄网站色视频免费国产| 国产偷国产偷亚洲高清人乐享 | 国产三级精品三级在线专1| 狠狠色丁香五月综合缴情婷婷五月| 法国少妇xxxx做受| 隔壁邻居是巨爆乳寡妇| 亚洲中文在线精品国产| 日韩无码| 国产熟妇人妻精品一区二区动漫| 无码精品一区二区三区在线| 国产亚洲日韩在线aaaa|